Continuous showers are the easiest and most efficient way to extract cannabinoids in a CLS. The butane is recycled by being pulled out of the bottom of the collection chamber, in the gas phase. It then passes through the recovery pump, up the the recovery manifold, and is condensed into the liquid phase by keeping the high pressure side of the recovery manifold (3) at ~100PSI.

Final image - Continuous Shower

Step 3 – Continuous Shower – open the high pressure recovery manifold (3)
Component #Component NameAbbreviationOpen/OnClosed/Off
1Extraction Column ValveECVx
2Low Pressure Recovery ManifoldRM2x
3High Pressure Recovery ManifoldRM3x
4Purge PortPPx
5Recovery CylinderRCx
6Vacuum PumpVPx
7Recovery PumpRPx
Step 3.1 – Continuous Shower – turn on recovery pump (RP) and run the continuous shower for 5-45 minutes – maintain a pressure of ~100 PSI on the high pressure side of the recovery manifold
Component #Component NameAbbreviationOpen/OnClosed/Off
1Extraction Column ValveECVx
2Low Pressure Recovery ManifoldRM2x
3High Pressure Recovery ManifoldRM3x
4Purge PortPPx
5Recovery CylinderRCx
6Vacuum PumpVPx
7Recovery PumpRPx

 

As always, if you have any questions please post them in the comments section. Your questions and time are valuable and we will make every attempt to help you through your process.