Continuous showers are the easiest and most efficient way to extract cannabinoids in a CLS. The butane is recycled by being pulled out of the bottom of the collection chamber, in the gas phase. It then passes through the recovery pump, up the the recovery manifold, and is condensed into the liquid phase by keeping the high pressure side of the recovery manifold (3) at ~100PSI.
Step 3 – Continuous Shower – open the high pressure recovery manifold (3) | ||||
Component # | Component Name | Abbreviation | Open/On | Closed/Off |
1 | Extraction Column Valve | ECV | x | |
2 | Low Pressure Recovery Manifold | RM2 | x | |
3 | High Pressure Recovery Manifold | RM3 | x | |
4 | Purge Port | PP | x | |
5 | Recovery Cylinder | RC | x | |
6 | Vacuum Pump | VP | x | |
7 | Recovery Pump | RP | x | |
Step 3.1 – Continuous Shower – turn on recovery pump (RP) and run the continuous shower for 5-45 minutes – maintain a pressure of ~100 PSI on the high pressure side of the recovery manifold | ||||
Component # | Component Name | Abbreviation | Open/On | Closed/Off |
1 | Extraction Column Valve | ECV | x | |
2 | Low Pressure Recovery Manifold | RM2 | x | |
3 | High Pressure Recovery Manifold | RM3 | x | |
4 | Purge Port | PP | x | |
5 | Recovery Cylinder | RC | x | |
6 | Vacuum Pump | VP | x | |
7 | Recovery Pump | RP | x |
As always, if you have any questions please post them in the comments section. Your questions and time are valuable and we will make every attempt to help you through your process.